Counter Location

Select a location in a well ventilated area, close to a grounded electrical outlet. If possible do not place the unit close to hot
and/or steaming machines.

Minimum Airflow Clearance

The minimum airflow clearance is: 4" (10.16 cm) in back and at sides; 12" (30.48 cm) on top, 4" (10.16) at sides and open to
the front.
!
IMPORTANT:
Condenser air is drawn in from the bottom of the rear panel and discharged out the top of the rear panel & side panels.
Failure to maintain clearance space will reduce capacity of the unit and cause premature compressor failure.
The Dispenser needs to be placed using 4" legs that are included.
MINIMUM 12" AIR
CLEARANCE AT TOP
C
W
ONNECTING THE
ATER
The Quest Elite series Juice Dispenser is designed to dispense juice at a high flow rate. It is very important that the incoming
water line be dedicated for use by the dispenser only and does not have other machines connected which could cause a
water surge, (i.e., a dishwasher, coffee maker, etc.).
!
IMPORTANT:
The water supply should be consistent with proper water quality standards (neutral pH of 7.0 to 8.0), and should not be
connected to a water softener. It is the installer's responsibility to ensure that all water connections to the dispenser are
sized, installed with adequate backflow protection and maintained to comply with Federal, State, and Local Laws.
© 2022, Marmon Foodservice Technologies Inc.
QUEST ELITE 4 Flavor Installation, Service & Decommissioning Manual

INSTALLATION REQUIREMENTS

Figure 4. Minimum Clearances
S
UPPLY
MINIMUM 4" AIR FLOW
CLEARANCE AT BACK
AND 4" AT SIDES
- 7 -