B.4

RS-232C Protocol

B.4.1

Parameters of the RS-232C Protocol

A protocol is a set of rules followed by various devices to send or receive data. The
parameters of the RS-232C protocol are stored in the battery-powered memory of the
printer. You can verify these parameters on the status printout as marked by the following
identifications:
H1: Baud rate
H2: Number of data bits
H3: Number of stop bits
H4: Parity
H5: Protocol logic
H6: Buffer-nearly-full threshold
H7: Buffer nearly-empty threshold
H8: Received data buffer size
The parameters can be changed from the printer operator panel. To change the value for the
serial interface parameters, see
Changing Serial Interface Parameters on page
This following section outlines the parameters and their values you can select on the
operator panel:
H1: Baud rate
Parameter value
Baud rate
12
1200
24
2400
48
4800
96
9600
19
19200
38
38400
57
57600
11
115200
The factory setting is 96 (9600 baud).
H2: Number of data bits
7 or 8. The factory setting is 8.
H3: Number of stop bits
1 or 2. The factory setting is 1.
Chapter 3 Using the Operator Panel, section 3.5.2
3-35.