Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
– Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive
(s).
– Replace the hard disk drives that are indicated by a lit status LED.
– Recreate the array.
– Restore data from backup.
Related links
– Removing 2.5-inch and 1.8-inch hot-swap drives
– Replacing 2.5-inch and 1.8-inch hot-swap drives
• 806f060d-0406ffff : Array [ComputerSystemElementName] has failed.
Drive 6 is part of an RAID array that is in the failed condition. To identify drives in the failed array all
member drives will report this message.
May also be shown as 806f060d0406ffff or 0x806f060d0406ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
– Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive
(s).
– Replace the hard disk drives that are indicated by a lit status LED.
– Recreate the array.
– Restore data from backup.
Related links
– Removing 2.5-inch and 1.8-inch hot-swap drives
– Replacing 2.5-inch and 1.8-inch hot-swap drives
Appendix C. Integrated management module II (IMM2) error messages