LeCroy USB Protocol Suite Advisor T3 User Manual page 85

Table of Contents

Advertisement

USB Protocol Suite User Manual
Menu
Setup
Display Options
Recording Options
Update Device
Launch CrossSync
Control Panel
Analyzer Network
All Connected
Devices
USB 3.0 Device/
Host Signal
parameters
Record (see "Recording Status" on page 86.)
Start
Stop
Upload Again
Reset SuperSpeed
Capture Engine
Generate (see "Traffic Generation (2.0)" on page 277)
Start/Stop
IntelliFrame
Generation Mode
Bitstream Generation
Mode
LeCroy Corporation
Function
Provides display options such as color, formats, and filters.
See "Display Options" on page 143.
Provides setup options for recording, triggering events and filtering.
See "Recording Options" on page 221.
Updates the BusEngine™ and Firmware manually.
See "Manual Updates to Firmware, BusEngine, and
Serdes BusEngine" on page 350.
Opens the CrossSync multiple-analyzer traffic synchronization
software (see CrossSync Control Panel on page 90). For more
infoemation, refer to the CrossSync User Manual.
Opens a dialog box for browsing to local and networked analyzers.
Within the dialog, click Add to browse. The dialog lists PCs that are
on the LAN. If a PC has an analyzer attached to it, and if DCOM
permissions have been set on the selected PC, clicking Select
establishes a connection.
See "Analyzer Network" on page 61.
Opens a dialog box with a list of analyzers connected to the host PC.
Lets you select an analyzer and update the BusEngine, Firmware,
and licensing information.
See "Analyzer Devices" on page 57.
Adds, removes, edits, loads, and saves USB 3.0 devices and lists
the device name, device cable, host name, host cable, and to what
the Profile Signal Settings apply.
Used to calibrate 3.0 connections. Also shows custom
device-to-analyzer and host-to-analyzer signal settings.
See "USB 3.0 Device/Host Signal Parameters" on page 62.
Causes the Analyzer to begin recording USB activity.
Causes the Analyzer to stop recording.
Allows you to upload a different portion of the captured trace if the
previous upload was only partially uploaded.
For USB 3.0 traffic capture, in some cases, the Analyzer might not
correctly lock onto the 5-GBps signals on power up, or it may unlock
after a long period of usage. To issue a soft reset to the SuperSpeed
capture engine, select this command. Note: After performing the
reset, you must retrain the link on your devices.
Starts traffic generation. After traffic generation has begun, the Start
command becomes Stop and lets you stop traffic generation.
Sets the mode of generation to IntelliFrame. Use before Start.
(2.0 only)
Sets the mode of generation to bitstream. Use before Start.
(2.0 only)
Chapter 4: Software Overview
71

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the USB Protocol Suite Advisor T3 and is the answer not in the manual?

Questions and answers

Table of Contents