Condition Monitoring
Machine Condition Monitoring with VIB-I/O Modules
peak value reaches increased values and the difference between peak values
and carpet value rises (see diagram below).
Fig. 2.2.4-3: Limited operating condition
A visible increase in the peak values and a rising difference between carpet
value and peak values are a sure indication for a bearing damage in progress.

2.2.4.2.3 Poor Operating Condition

Peak values in poor operating condition, a large distance between peak values
and carpet values and a possible increase in the carpet value, indicate the
presence of a bearing damage.
Fig. 2.2.4-4: Poor operating condition
When the peak values are in poor operating condition and the peak values are
approx. three times the carpet value, the risk of a bearing damage is very high.