Importing user alarms

9.1

Overview

The procedure overview below describes how to copy the SINUMERIK user alarm files directly
from an NCU and import them into TIA Portal.
Alternatively, the import of alarm files in CSV format is also supported. This can, for example,
be created if you manage your language-dependent text files with SINUMERIK Integrate
Access My Machine /P2P.
Requirement
● The user alarms are available in SINUMERIK Operate (or AMM/P2P).
● A SINUMERIK NCU or device proxy (PLC 300) is inserted in the TIA Portal project.
Note
System-specific differences
Import and storage of the alarm texts can differ system-specifically in the TIA Portal. Note the
corresponding subchapter for the system used, e.g. SINUMERIK 840D sl.
Procedure overview
To use SINUMERIK user alarms in the TIA Portal, proceed as follows:
Ste
Description
p
1
Make the user alarm files available in the required languages. You can copy the files via the SINUMERIK Operate user
interface, for example to a USB flash drive (Page 164).
2
Check whether all languages or language variants in which you want to import SINUMERIK user alarms are enabled
as project languages in the TIA Portal.
● To check which exported alarm files correspond to which project languages in the TIA Portal, refer to
Section Language assignment in language-dependent texts (Page 165).
● How to activate the project languages is described in Section Enable project languages (Page 167).
3
Import the SINUMERIK user alarms into the TIA Portal (Page 168).
SINUMERIK STEP 7 Toolbox V15.1
Configuration Manual, 12/2018, A5E46279635B AA
9
163