IPVK/6296 Series IP videokit
Art. 4901
Digital codelock module
PROGRAMMING MODE 1 DEFAULT MODE, JPL = A
Follow the steps below to set the codelock to mode 1:
1. Disconnect the power from the Art. 4901 codelock;
2. Short out terminals and SW2;
3. Press and hold down button 1
while the power is switched back ON;
4. When power is restored to the codelock wait for the module
to emit a single beep and the red status LED (Fig.1,
once;
5. Listen for the confirmation tone and wait for the red status
LED (Fig.1,
B
) to flash once again;
6. Release button 1
and remove the short between terminals
and SW2;
7. Set the jumper JPL to the desired position.
BACK LIGHT AND BUTTON OPERATION
If the back light programming mode is set to mode 1 (with jumper JPL in either the A or B position) when a button is pressed on the
keypad the back light will switch to full brightness for approximately 10 seconds.
After this time the back light will either switch OFF or switch back to low brightness (depending on the jumper position) unless another
button has been pressed within the 10 second period in which case the back light will stay on full brightness for a further 10 seconds.
The exception to this is if the back light programming mode is set to mode 2, i.e. the back light will be on full brightness all of the
time or if the jumper is removed the back light will be disabled.
PROGRAMMING
• Enter the ENGINEER'S CODE: first time type six times 1 (111111
factory preset) and press ENTER (The red LED will illuminate);
• Confirm ENGINEER'S CODE (typing again the same) or
type the new code (4 to 8 digits) then press ENTER (Melo-
dy). Pressing twice the ENTER button without changing the
ENGINEER'S CODE, will exit from the programming;
• Enter the code (4 to 8 digits) to enable RELAY 1 or re-enter the
existing code then press ENTER (Melody);
• Enter the RELAY 1 operation time (2 digits 01 to 99 I.E. 05=5
seconds, 00= remain open time) or re-enter the existing time
then press ENTER (Melody);
• Enter the code (4 to 8 digits) to enable RELAY 2 or re-enter the
existing code then press ENTER (Melody);
• Enter the RELAY 2 operation time (2 digits 01 to 99 I.E. 05=5
seconds, 00= remain open time) or re-enter the existing time
then press ENTER (Melody);
• Enter the code (4 to 8 digits) to enable RELAY 3 or re-enter the
existing code then press ENTER (Melody);
• Enter the RELAY 3 operation time (2 digits 01 to 99 I.E. 05=5
seconds, 00= remain open time) or re-enter the existing time
then press ENTER (Melody);
• The system is ready to use (the red LED will be off ).
PROGRAMMING NOTES
• After pressing enter following a command, press ENTER a fur-
ther twice to exit the programming menu.
RETURN SYSTEM TO PRESET ENGINEER'S FACTORY CODE
• Turn off power to code lock;
• Keep ENTER button pressed while turning the power back on;
• Release ENTER button;
• The engineer's code is now set to 111111 (six times one).
IPVK/6296 Series - Installation handbook
and keep it pressed down
B
) to flash
- 11 -
PROGRAMMING MODE 2
Follow the steps below to set the codelock to mode 2:
1. Disconnect the power from the Art. 4901 codelock;
2. Short out terminals and SW2;
3. Press and hold down button 2
while the power is switched back ON;
4. When power is restored to the codelock wait for the module
to emit a double beep and the red status LED (Fig.1,
flash once;
5. Listen for the confirmation tone and wait for the red status
LED (Fig.1,
B
) to flash once again;
6. Release button 2
and remove the short between terminals
and SW2;
7. Set the jumper JPL to the desired position.
ENTER THE
"ENGINEER'S CODE"
Press Enter
(Red LED will
be ON)
CONFIRM
OR CHANGE
Press Enter
"ENGINEER'S CODE"
(melody)
ENTER
"ACCESS 1 CODE"
Press Enter
(melody)
ENTER
"ACCESS 1 TIME"
Press Enter
(melody)
ENTER
"ACCESS 2 CODE"
Press Enter
(melody)
ENTER
"ACCESS 2 TIME"
Press Enter
(melody)
ENTER
"ACCESS 3 CODE"
Press Enter
(melody)
ENTER
"ACCESS 3 TIME"
Press Enter
(melody)
SYSTEM
READY TO USE
and keep it pressed down
B
) to
First time six times
1 "111111" factory
preset
Type again six times
"1" or the new en-
gineer's code 4 to 8
digits
Code to enable relay 1
4 to 8 digits
Two digits (01 to 99)
i.E. 05=5 Seconds
00= remain open
Code to enable relay 2
4 to 8 digits
Two digits (01 to 99)
i.E. 05=5 Seconds
Code to enable relay 3
4 to 8 digits
Two digits (01 to 99)
i.E. 05=5 Seconds
Red led will be off