Videx 4212V Installation Instructions Manual

Videx 4212V Installation Instructions Manual

4000 series vandal resistant range
Hide thumbs Also See for 4212V:

Advertisement

4000 Series Vandal Resistant Range
Art. 4212V-4212RV
Art.  4212V
Fig. 1 Front view
Dry contact output
V.PB.CHIP
Capacitor discharge
Balanced V1, V2
Balance
Coax V2=V, V1
12T
not used
GNDV
V2/V
V1
RS485
PTE
BUS TERMINATION
TRD
Open
NO
Close
C
A
NC
RS485
B
SL
GND
BS
D0
L
D1
WIEGAND
LR
+12
LG
GND
OC OUTPUT
Made in Italy
Fig. 2 Back view
Art. 4212V-4212RV - Installation instructions
Audio/video digital front panel
Wide angle colour
camera
Speaker
Display
Keyboard
Door Open Relay
Operating Mode jumper
Video signal setup
switch
Connection
terminals
Art.  4212RV
Dry contact output
V.PB.CHIP
Capacitor discharge
Balanced V1, V2
Balance
Coax V2=V, V1
12T
not used
GNDV
V2/V
V1
RS485
PTE
BUS TERMINATION
TRD
Open
NO
Close
C
A
NC
RS485
B
SL
GND
BS
D0
L
D1
WIEGAND
LR
+12
LG
GND
OC OUTPUT
Made in Italy
1
Voice annunciation
speech adjustment
Audio balance
adjustment
Microphone
volume adjustment
Speaker
volume adjustment
RS485
bus termination switch
RS485
bus connection terminals
Wiegand
connection terminals
66250203-EN - V0.3 - 10/07/15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4212V and is the answer not in the manual?

Questions and answers

Summary of Contents for Videx 4212V

  • Page 1 Wiegand Balanced V1, V2 Balance Coax V2=V, V1 connection terminals not used GNDV V2/V RS485 BUS TERMINATION Open Close RS485 WIEGAND − OC OUTPUT Made in Italy Fig. 2 Back view Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...
  • Page 2: Versions Available

    ART. 4212RV, ART. 4212RV/F, ART. 4212RV/SA As Art. 4212V but using a keypad with 15 blue back lit buttons 3 of which are navigation buttons used for the repertory name facility, 10 are numeric buttons (0..9) plus “ENTER” and “CLEAR” buttons. The tenants can be called by dialling the relevant apartment number or by searching the relevant name using the repertory name function.
  • Page 3 If bus is busy or intercom is not present, “BUSY!” message will appear on the screen. If no answer after 40 seconds the call will be cleared. If the call is answered a conversation can begin. calling Fig. 6 Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...
  • Page 4: Acoustic Signals

    - “ ” to scroll forward; - “ ” to alternate between capital and lower case letters. For instance, to type the name “VIDEX” it is necessary to press: 3 times “8” button = “V”; 3 times “4” button = “I”;...
  • Page 5: Adding Users

    » if user has previously selected “Single” the panel will enter the User Code Search: › if searched code is present, panel will show” ITEM SAVED” message; › if searched code isn’t present in memory, panel will show “NOT FOUND!”. Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...
  • Page 6 – if user has previously selected search by key, pass the card/fob over the symbol. › if searched key is present, panel will show ” ITEM SAVED” message; › if searched key isn’t present in memory, panel will show “NOT FOUND!”. Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...
  • Page 7: Programming Parameters

    • select user searching by name or flat; • press “3” to enter into edit mode; • type new access code; • press to save or to delete characters or exit edit mode without saving. Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...
  • Page 8 The tags (key or fob) allow users to open the door. Three fob code lengths are supported (2, 3 & 4 bytes). It is specified by Tag width parameter (see “Fob width” on pag. 15). User can be linked to more than one access code. The modify routine is described in “Key managing” on pag. 6 Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...
  • Page 9: Switch Time

    • press “5” to enter into edit mode; • enter time is seconds: it must be between “1“ and “250”; • press to save or to delete characters or exit edit mode without saving. Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...
  • Page 10: Time Parameters

    2. press again “1” to enter into edit mode; 3. press “1” to switch from EU to US and viceversa; 4. press to save or to exit edit mode without saving. Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...
  • Page 11: Relay Time

    • press “5” to enter edit mode; • edit relay time: it must be between “1“ and “255”; • press to save or to delete characters or exit edit mode without saving. Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...
  • Page 12: Code Parameters

    Add routine • press “4” to enter into edit mode; • press “3” to add and then present a card to the reader when asked; • press to exit edit mode. Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...
  • Page 13: System Settings

    In Fob + Code, key and code are linked together. Single code is linked with single key.A user must enter a code and present a key to open the door. Parameter can be changed only through PC programming routine. Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...
  • Page 14 Wiegand controller replies by setting the LG terminal to 0V then the key is accepted and the display will show door open. If the Wiegand control does not reply then the panel will show ‘NOT FOUND’ . Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...
  • Page 15 This parameters can only e set using the PC software. When set to 2 bytes it will send the 2 least significant bytes of the fob, when set to 3 will be the 3 least significant bytes and 4 will be the four least significant bytes. Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...
  • Page 16 OC OUTPUT Open collector output TECHNICAL SPECIFICATION Memory capacity: 998 users - 2800 keys - 2800 codes Working voltage: 12 Vdc +/- 10% Max absorb: about 350mA Working Temperature: -10 +50 °C Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...
  • Page 17 4000 Series Vandal Resistant Range Art. 4212V-4212RV Audio/video digital front panel Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...
  • Page 18 4000 Series Vandal Resistant Range Art. 4212V-4212RV Audio/video digital front panel Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...
  • Page 19 3. Fix the plate to the flush mounting box using the screwdriver provided (torx end) and the pin machine torx screws (Fig. 5). Do not over tighten the screws more than necessary. Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...
  • Page 20: Customer Support

    European Directives 2004/108/ECC (EMC); www.videx.it - technical@videx.it www.videx-security.com 2006/95/ECC (LVD) and 93/68/ECC (CE marking). Tel: +39 0734-631669 Tech Line: 0191 224 3174 Fax: +39 0734-632475 Fax: 0191 224 1559 Art. 4212V-4212RV - Installation instructions 66250203-EN - V0.3 - 10/07/15...