Install the PowerGlide Plus Hydraulic System
Remove the Orifice Fittings
Before populating the hydraulic fittings on the AutoBoom valve, it is necessary to remove orifice fittings from
the valve in the PowerGlide Plus system. Failure to remove these fittings from the valve will restrict the down
speed of the booms when the system is enabled.
Manual No. 016-0230-013
WARNING
The machine must remain stationary and
switched off, with the booms unfolded and
supported, during installation or maintenance.
CAUTION
When installing AutoBoom hydraulics or
performing diagnostics, maintenance, or routine
service, ensure precautions are taken to
prevent any foreign material from being
introduced into the machine's hydraulic system.
Objects or materials that are able to bypass the
machine's hydraulic filtration system will reduce
performance and possibly cause damage to the
AutoBoom hydraulic valve.
NOTICE
The appearance of the AutoBoom hydraulic
valve may vary slightly from the images
contained in this manual. However, the fittings,
hose connections, and cable connections
remain the same.
PowerGlide Plus
23