4.3.4.2
DIAGNOSTICS
Advanced system diagnostics are available for display. The
diagnostics screen continually updates its values so they're always
live. The type of information shown, along with many others include:
-
System Voltage.
-
System Current.
-
Valve status and current draws.
Flame detection status along with AC and DC values.
-
-
Burner run time.
-
Average firing rate.
Flame fail count.
-
Daily energy consumption.
-
4.3.4.3
FLAME DIAGNOSTICS
The Flame Diagnostics screen shows a real time evaluation of the
Pilot status. This includes the High and Low (DC) voltage in milli volts
(mV). Also, the (AC) voltage in mV.
Flame Diagnostics will record the number of Flame Fails as well as
Relights. On the right side of the screen you will get a graphical
representation of the flame health ranging from Bad to Excellent.
The graph is in the form of a vertical bar.
4.3.4.4
STATUS PRIORITY
The Status Priority screen allows you to change the focus of the
Status Screen from Bath to Firing Rate. This of course makes the
selected priority the most prominent on the status screen to make
the information more relevant for the application of the unit.
To change the Priority simply use the
priority from Bath to Firing Rate or back again.
The right side of the screen shows the various layouts of the status
screen.
The right portion of this screen shows the different layouts in accordance to the selected priority.
+
and
keys to alternate the
Section 4: OPERATIONS and MAINTENANCE
V 4.0
Page 68 of 85