Configuring traps
A trap is a condition that SNMP monitors on Mirage 304K.
1. Select MENU > Communications > SNMP > Trap Configuration.
2. Select the trap you want to enable and select Enter.
The available traps are:
•
Lamp Life
•
Lamp Fault
•
Fan Stall
•
Thermal Sensors
•
Power
•
Video Signal
3. To enable additional traps, repeat step 2.
Defining a trap IP address
When a trap condition is met, a notification is sent using an SNMP notification to one or more specified
IP addresses.
1. Select MENU > Communications > SNMP.
2. Select Address 1.
3. Use the up and down arrows to enter an IP address.
4. To confirm the address, select Enter.
5. To add a second and third IP address, repeat steps 2 to 4 for Address 2 and Address 3.
Restoring factory default settings
Restoring factory settings removes all custom device settings.
Only Christie qualified technicians can reset factory defaults.
1. From the display panel, select MENU > Admin > Service.
2. Enter the service password.
The password is only required for the display panel and not the web user interface.
3. Select Reset Factory Defaults.
All customized settings are set to the default factory settings.
4. At the confirmation prompt, select Reset.