Setting the SNMP read community string
The SNMP read community string is similar to a userid or password that allows access to the device.
1. Select MENU > Communications > SNMP > SNMP Read Community.
2. Use the up and down arrows to enter the read community string.
3. To confirm your selection, select Enter.
Configuring traps
A trap is a condition that SNMP monitors on Crimson.
1. Select MENU > Communications > SNMP > Trap Configuration.
2. Select the trap you want to enable and select Enter.
The available traps are:
•
Fan Stall
•
Thermal Sensors
•
Power
3. To enable additional traps, repeat step 2.
Defining a trap IP address
When a trap condition is met, a notification is sent using an SNMP notification to one or more specified
IP addresses.
1. Select MENU > Communications > SNMP.
2. Select Address 1.
3. Use the up and down arrows to enter an IP address.
4. To confirm the address, select Enter.
5. To add a second and third IP address, repeat steps 2 to 4 for Address 2 and Address 3.
Restoring factory default settings
Restoring factory settings removes all custom device settings.
Only Christie qualified technicians can reset factory defaults.
1. From the display panel, select MENU > Admin > Service.
2. Enter the service password.
3. Select Reset Factory Defaults.
All customized settings are set to the default factory settings.
4. At the confirmation prompt, select Reset.
Crimson User Guide–Mirage HD25, Mirage WU25, Crimson HD25, Crimson WU25
020-102649-01 Rev. 1 (04-2018)
Copyright
2018 Christie Digital Systems USA, Inc. All rights reserved.
©