Activity #2: Field Testing For Object Detection And Infrared Interference - Parallax Boe-Bot Student Manual

Hide thumbs Also See for Boe-Bot:
Table of Contents

Advertisement

Page 242 · Robotics with the Boe-Bot
Change the
DEBUG
Change the variable name from
need to do this in four places in the program.
Change the
FREQOUT
Change the input register monitored by the
to
.
IN0
Repeat the testing steps in this activity for the right IR pair; with the IR LED
circuit connected to P2 and the detector connected to P0.
ACTIVITY #2: FIELD TESTING FOR OBJECT DETECTION AND
INFRARED INTERFERENCE
In this activity, you will build and test indicator LEDs that will tell you if an object is
detected without the help of the Debug Terminal. This is handy if you are not near a PC
or laptop, and you need to trouble-shoot your IR detector circuits. You will also write a
program to "sniff" for infrared interference from fluorescent lights. Some fluorescent
lights send signals that resemble the signal sent by your infrared LEDs. The device
inside a fluorescent light fixture that controls voltage for the lamp is called the ballast.
Some ballasts operate in the same frequency range of your IR detector, 38.5 kHz, which
in turn causes the lamp to emit a signal at this frequency. When you integrate IR object
detection with navigation, this interference can cause some bizarre Boe-Bot behavior!
Rebuilding the LED Indicator Circuits
These are the same LED indicator circuits that you used with the whiskers.
Parts List:
(2) Red LEDs
(2) Resistors – 220 Ω (red-red-brown)
Disconnect power from your board and servos.
Build the circuit shown in Figure 7-6 using Figure 7-7 as a reference.
statement, title and comments to refer to the right IR pair.
irDetectLeft
command's
argument from 8 to 2.
Pin
to
irDetectRight
variable from
irDetectRight
. You will
IN9