In order to avoid oscillations of the drive while it is at standstill, amplification is re-
duced to 50 % of the parameterized value for small position deviations
The following behavior may indicate that the controller parameters are not config-
ured properly:
− drive is very loud
− drive vibrates
− frequent contouring errors
− inexact control
For the setting options of other control parameters, e.g. speed controller and accel-
eration pilot control, refer to the operating instructions of the frequency inverter.
Note:
04/08
04/08
Amplification [%]
100
50
-0.25 0.00
-0.50
Optimize the settings in actual operating conditions, as control parame-
ters for speed controller and acceleration pilot control depend on actual
load. Optimize with different load types to obtain a good control behav-
ior in all situations.
Application manual Positioning
Application manual Positioning
Control deviation
0.25
0.50
of position [°]
111
111
Need help?
Do you have a question about the ACTIVE CUBE Series and is the answer not in the manual?
Questions and answers