Target Window - BONFIGLIOLI Vectron ACTIVE CUBE Series Applications Manual

Positioning
Hide thumbs Also See for ACTIVE CUBE Series:
Table of Contents

Advertisement

4.8.4
The target window monitors the current position after completion of a positioning
operation. A positioning operation is complete as soon as the current position is in
the target window. Via parameter
which distance from the target position the signal "60 – Target Position Reached" is
set. This setting is valid both for the positive and negative direction.
If the parameter value is set to 0, the operation will be complete as soon as the
target position is reached.
Via parameter
be in the target window before "60 – Target Position Reached" is signaled.
Note:
04/08
04/08

Target window

Target Window Time
Parameter
No.
Description
1165 Target Window
1166 Target Window Time
Target window
Target Window
1165
Target Window Time
Position
Target position
Target position reached
The size of the target window affects the automatic sequence of motion
blocks because the positioning operation requires a higher precision in
the case of a small target window (small tolerance). The following mo-
tion block is started when the target window is reached.
Application manual Positioning
Application manual Positioning
Target Window
1166, you can define how long the axis must
Min.
0 u
1 ms
Output signals
Operation modes for digital outputs
60 - Target Position Reached
160 - Inv. Arrived at desired Position
1166
Signal source:
282 - Target Position Reached
Target
window time
1165, you can define as from
Setting
Max.
Fact. sett.
20
2
u
182 u
65 535 ms
1 ms
Target window
t
t
:
99
99