AT commands
Parameter range
0x11 - 0x16F bytes
Default
0x13F

AP (API Mode)

Sets or reads the UART API mode.
Parameter range
0 - 2
The following settings are allowed:
Parameter Description
Transparent mode, API mode is off. All UART input and output is raw data and the
0
device uses the RO parameter to delineate packets.
1
API Mode Without Escapes. The device packetizes all UART input and output data in API
format, without escape sequences.
2
API Mode With Escapes. The device is in API mode and inserts escaped sequences to
allow for control characters. The device passes XON, XOFF, Escape, and the 0x7E
delimiter as data.
Default
0

AO (API Options)

The API data frame output format for RF packets received. This parameter applies to both the
UART and SPI interfaces.
Parameter range
0, 1
Parameter
Description
0
API Rx Indicator - 0x90, this is for standard data frames.
1
API Explicit Rx Indicator - 0x91, this is for Explicit Addressing data frames.
Default
0

I/O settings commands

The following AT commands are I/O settings commands.