Change Signal Layout Use; Function Number - Panasonic LIQI Manual

Table of Contents

Advertisement

-Change signal layout use

Classificat
No.
Parameter Title
ion
00
4
SI1 input selection
01
4
SI2 input selection
02
4
SI3 input selection
03
4
SI4 input selection
04
4
SI5 input selection
05
4
SI6 input selection

Function number

Title
Invalid
Positive direction over-travel
Inhibition input
Negative direction over-travel
Inhibition input
Servo-ON input
Alarm clear input
(Do not setup.)
Gain switching input
Deviation counter clear input
Command pulse inhibition input
Torque limit switching input
Damping control switching input 1
Damping control switching input 2
Electronic gear switching input 1
Electronic gear switching input 2
(Do not setup.)
Forced alarm input
(Do not setup.)
Attention :
Do not setup to value other than that specified in the table.
Do not assign specific function to 2 or more signals.
Duplicated assignment will cause Err33.0 I/F input multiple assignment error 1 or 33.1 I/F
Input multiple assignment error 2.
*1 Servo-on input signal(SRV-ON)must be used to enable servo-on.
*2 When using control mode switching input(C-MODE), set the signal to all control modes.
If the signal is set to only 1 or 2 control modes, Err33.2 I/F input function number error 1 or Err33.3 I/F input function
number 2 will be generated.
The control input pin set to invalid state does not affect any operation.
Function(servo-on input, alarm clear, etc.)to be used in multiple control modes must be assigned to the same pin
with correct logical arrangement. Incorrect setting will cause Err33.0 I/F input multiple assignment
error 1 or Err33.1 I/F input multiple assignment error 2.
*3 Deviation counter clear input(CL)can be assigned only to SI7 input.
Wrong assignment will cause Err33.6 Counter clear assignment error.
Set range
Unit
Assign function to SI1 input.
this parameter is presented in hexadecimal.
0 00FFFFFFh
-
000000**h
** with the function number.
0 00FFFFFFh
-
0 00FFFFFFh
-
Assign functions to SI2 to SI6 inputs.
0 00FFFFFFh
-
These parameters are presented in hexadecimals.
Setup procedure is the same as described for Pr.4.00.
0 00FFFFFFh
-
0 00FFFFFFh
-
Symbol
-
POT
NOT
SRV-ON
A-CLR
-
GAIN
CL
INH
TL-SEL
VS-SEL1
VS-SEL2
DIV1
DIV2
-
E-STOP
-
Motor Business Unit, Home Appliances Company, Panasonic
SR-DSV10739
Function
Setup value
a-contact
b-contact
00h
(Do not setup.)
01h
81h
02h
82h
03h
83h
04h
(Do not setup.)
05h
85h
06h
86h
07h
(Do not setup.)
08h
88h
09h
89h
0Ah
8Ah
0Bh
8Bh
0Ch
8Ch
0Dh
8Dh
0Eh 13h
8Eh 93h
14h
94h
15h
95h