Mechanical brake action at stalling
Pr4.37
setup
Mechanical brake action at running
Pr4.38
setup
Pr4.39 Brake release speed setup
Pr4.40 Warning output 1 selection
Pr4.41 Warning output 2 selection
Setup
Alarm
Value
[0]
---
1
Overload protection
2
Over-regeneration alarm
3
Battery alarm
4
Fan alarm
Encoder communication
5
Alarm
6
Encoder overheat alarm
7
Oscillation detection alarm Oscillation or vibration is detected.
8
Lifetime detection alarm
9
Pr4.42
2
nd
in position range
LIQI
Range
0 – 10000
Range
0 – 10000
Range
30 – 3000
Range
0 – 11
Range
0 – 11
Content
Ored of all alarms.
Load factor is 85% or more the protection level.
Regenerative factor is 85% or more the protection
level.
Battery voltage is 3.2V or lower.
Fan has stopped for 1 sec.
The number of successive encoder communication
errors exceeds the specified value.
The encoder detects overheat alarm.
Life expectancy of capacitor or fan become short.
Range
0 – 262144
* for more detail please refer Panasonic A5 manual
Page 11
Default
Unit
0
1ms
Default
Unit
0
1ms
Default
Unit
30
r/min
Default
Unit
0
-
Default
Unit
0
-
Default
Unit
10
-