Mod-2202 And Mod-2402: 2-Port (Serial Terminals) Power Supply - Comtrol DeviceMaster MOD Series Hardware Installation And Configuration Manual

Table of Contents

Advertisement

MOD-2202 and MOD-2402: 2-Port (Serial Terminals) Power Supply

DeviceMaster MOD | UP Hardware Installation and Configuration Guide: 2000630 Rev. B
This table provides the specifications to purchase a power supply for a
DeviceMaster 2-port (MOD-2202 and MOD-2402) with serial terminals DIN rail.
Signal
Ground†
† Wire gauge: AWG 12-22
Signal Ground is used to connect RS-232 devices
later in the installation.
DeviceMaster UP 2-Port DIN Rail (Serial Terminals)
Output voltage†
Current†
Power
† Any power supply that meets current consumption, voltage,
power, and connector pinouts requirements can be used.
External Power Supply Specifications
Chassis
Ground†
Return†
(MOD-2202 and MOD-2402)
External Power Supply
6-30VDC
100 mA (Min) @ 24VDC
2.5 W
6-30VDC
Positive†
External Power Supply Specifications - 81