Caution
66 - Managing the DeviceMaster
Make sure that power is not interrupted while uploading Bootloader.
Power interruption while uploading Bootloader will require that the
DeviceMaster must be sent into Comtrol so that it can be reflashed.
If you are not successful uploading firmware into the DeviceMaster, do
not upload Bootloader.
1. If you have not done so, install PortVision DX
Page 32) and Scan the network.
2. If necessary, check the Bootloader version (Checking the Bootloader Version)
and download the latest version.
3. Right-click the DeviceMaster for which you want to update, click Advanced >
Upload Firmware, browse to the Bootloader .cmtl file, and then click Open.
4. Click Yes to the Upload Firmware message that warns you that this is a
sensitive process.