Hardware Installation
Caution
Caution
18 - Hardware Installation
Observe proper ESD techniques when connecting and disconnecting
the DeviceMaster.
Insert the earth ground wire into the earth ground screw terminal.
Insert the DC positive wire into the
positive screw terminal and the DC
return wire into the return screw
terminal.
Refer to
1-Port Panel Mount 5-30VDC
Power Supply
on Page 79 for detailed
power requirements.
Use a small flat head screw to lock the
wires into place.
Verify that each wire has been tightened
securely.
Plug the screw terminal power
connector into the DeviceMaster.
Note: Align the plug properly. The scalloped side of
the screw terminal power connector should be
aligned with the scalloped side of the power
jack on the unit.
Connect the power supply to a power source.
Go to
Step 4
to verify that the DeviceMaster is
functioning properly.
4. Verify that the Status LED has completed the boot cycle
and network connection for the DeviceMaster is functioning properly using the
table below.
1-Port Enclosed LED Descriptions
The amber Status LED on the device is lit, indicating you have power
and it has completed the boot cycle.
Note: The Status LED flashes while booting and it takes
Status
approximately 15 seconds for the Bootloader to complete the
cycle. When the Bootloader completes the cycle, the LED has a
solid, steady light that blinks approximately every 10 seconds.
If the red Link/Act LED is lit, it indicates a working Ethernet
Link/Act
connection.
If the red Duplex LED is lit, it indicates full-duplex activity.
Duplex
If the red 100 LED is lit, it indicates a working 100 MB Ethernet
connection (100 MB network, only). If the LED is not lit, it indicates
100
a 10 MB Ethernet connection.
Note: For additional LED information, go to the
Do not connect RS-422/485 devices until the IP address is configured
and an appropriate port interface type has been configured. The
default port setting is RS-232.
5. Go to
Preparing the DeviceMaster for Configuration
PortVision DX, configure the network settings, and if necessary, upload the
appropriate protocol firmware on the DeviceMaster.
DeviceMaster MOD | UP Hardware Installation and Configuration Guide: 2000630 Rev. B
-
Earth Gnd
5-30VDC
+
Wire gauge:
AWG 12-22
Status LED table