Three Water Valves Test; Drain And Clutch Test; Drain And Spin Test; Alarm History Test - Frigidaire FFLE3911QW Technical & Service Manual

Table of Contents

Advertisement

15.10 Three Water Valves Test

Selector position
Purpose of the test
Activated components
UI behaviour
Working conditions

15.11 Drain and Clutch Test

Selector position
Purpose of the test
Activated components
UI behaviour
Working conditions

15.12 Drain and Spin Test

Selector position
Purpose of the test
Activated components
UI behaviour
Working conditions

15.13 Alarm History Test

Selector position
Purpose of the test
Activated components
UI behaviour
Working conditions
Turn 4 clicks clockwise from the top
To test both hot and cold and, if present, the softener water valves and the softener
siphon drains fully, agitate function
Door lock, three water valves, main motor
None
Door locked, Add while water level lower than 55mm, for max. 5 minutes. The clutch
moves to the agitate position, if it was in spin. Agitate begins when the water level is
reached
Turn 5 clicks clockwise from the top
Drain system with the clutch mechanism
Door lock, drain pump, clutch actuator
None
Door locked, drum stop, run clutch to spin mode and drain until empty +10 seconds
more. Run clutch actuator for about 100 seconds
Turn 6 clicks clockwise from the top
Verify drain system, and Pressure Sensor calibration procedure
Door lock, main motor, drain pump
None
Door locked, empty tub water level <5mm, if not the drain will run, if not in spin
mode the clutch actuator will run to spin position, spin up to maximum speed
Turn 7 clicks clockwise from the top
Communicate alarm history
Buzzer
A series of beeps separated by a short pause for one character and a long pause to
move to the second character. Press selector for next stored alarm. Example, count
12 beeps is a C
Drum stopped, Door unlocked
152

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fflg3911qwFfle4033qwFflg4033qw

Table of Contents