E61: Heater Relay Failure; E61 Heater Relay Failure - Frigidaire FFLE3911QW Technical & Service Manual

Table of Contents

Advertisement

E61: Heater Relay Failure

E61
Heater relay stuck open or closed and defective wiring
Checks to perform:
Measure resistance between the connectors RELAY
COM and RELAY NO terminals of the Electronic
control board . (See Fig. 1) Is Resistance value not "0"?
Detach the connectors and measure between the
heating element and the earth contact. (See Fig.2) Is
Resistance value not "0"?
Check / Replace the wiring and repeat the Diagnostic
Cycle to check for any further alarms.
Y
E
S
Y
E
S
WARNING
Check that all the connectors are correctly inserted
Replace the Control board and repeat the Diagnostic
NO
Cycle to check for any further alarms.
Replace the heating element and repeat the Diagnostic
NO
Cycle to check for any further alarms.