Frigidaire FFLE3911QW Technical & Service Manual page 155

Table of Contents

Advertisement

15.14 Alarms Summary Table
Alarm
S. NO.
Alarm Code
Description
8
E42
Door / Lid lock
failure
9
E43
Door / Lid lock
triac failure
10
E44
Door / Lid
closed sensing
failure
11
E45
Door / Lid triac
sensing failure
12
E55
Motor under-
speed Failure
13
E58
Motor over
current
14
E59
Motor not
following
15
E5A
Motor control
overheating
16
E5H
Motor control
under voltage
Fault
Possible Fault
Condition
Door will not
Door lock
unlock after 3
Low input AC voltage Wiring
attempts
door lock triac
Door lock
sensing and triac
Wiring or Main Board
control status
difference
Wrong input
Wiring or Main Board
signal to
microprocessor
Incorrect triac
Wiring or Main Board
sense signal
During spin, the
Foam or drum weight
motor speed
overload
is lower than
Drum mechanical drag
the target for 2
Motor
minutes
Drain pump
High current on
Foam or drum weight
motor phase
overload
(>4.5A)
Motor
Wiring or Motor Control
Board
No rotation
Drum mechanical locked
detected for 3
Motor
seconds
Wiring or Motor Control
Board
High
Drum weight overload
temperature
Motor Control Board
on heat sink
Motor
(>88°C) or NTC
of motor control
board open
DC bus voltage
Low input AC voltage
below the
Wiring or Motor Control
minimum
Board
(175V)
Main board
154
Action
Machine Action/
to
Status
Clear
Cycle Paused
START
RESET
Cycle abort
RESET
Safety drain
Cycle abort
RESET
Safety drain
Cycle abort
RESET
Safety drain
Cycle abort
ON/OFF
RESET
Cycle abort
ON/OFF
RESET
Cycle abort
ON/OFF
RESET
Cycle abort
ON/OFF
RESET
Cycle abort
ON/OFF
RESET
Page
No
171
172
173
174
175
177
179
181
183

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fflg3911qwFfle4033qwFflg4033qw

Table of Contents