Diagnostic System - Ffle3911Qw And Fflg4033Qw (Washer); Reading Error Codes; Diagnostic Mode; Entering Diagnostic Mode - Frigidaire FFLE3911QW Technical & Service Manual

Table of Contents

Advertisement

15. Diagnostic System - FFLE3911QW and FFLG4033QW
This information is intended for qualified technicians only.
CAUTION
DISCONNECT ELECTRICAL CURRENT BEFORE
SERVICING
Acronyms:
CW - Clockwise
CCW - Counter Clockwise
Cold Power On - Unit plugged in for the first time

15.1 Reading Error Codes

Enter the Diagnostic Mode to read error codes (Refer to the
instructions below on how to enter this mode):
The last recorded error code will be displayed first.
Start/Pause/Cancel buttons should be pressed
momentarily (any time less than 1sec) to cycle through
the last 5 error codes recorded.
E00 signifies no error code and is accompanied by no
buzzer beeps.
Press and hold the Start/Pause/Cancel button for a
duration >= 4 seconds to clear all error codes.
Error Code Display Method -
Buzzer equipped
1.
The buzzer beeps the same number of times as the first
digit of the error code (0.5 sec ON/ 0.5 sec OFF).
For example:
If the first digit is 3, the buzzer sequence will be 0.5 seconds
ON/0.5 seconds OFF/0.5 seconds ON/0.5 seconds OFF/0.5
seconds ON/0.5 seconds OFF. A, B, C, D, E, F corresponds
to the buzzer digit readings of 10, 11, 12, 13, 14, and 15,
respectively.
2.
The buzzer stays silent for 2 seconds.
3.
The buzzer beeps the same number of times as the
second digit of the error code (0.5 seconds ON/0.5 seconds
OFF).
4.
The buzzer stays silent until the Start/Pause/Cancel
buttons are pressed momentarily to read the next error
code.

15.2 Diagnostic Mode

Use this mode under the following conditions:
In a factory assembly line to perform a manual test of
the machine functionality (final assembly test)
By service personell to check for faults and repair the
machine
In the labs to check the machine functions
15.3 Entering the Diagnostic
Mode
Follow the instructions given below to enter the Diagnostic
Mode:
1.
Plug the unit in or do a full control reset, which is
described in other documents. Set the Cycle Selector knob
at the 9 o'clock (presoak) position and the temperature
knob at the far left CCW position hot for LC1 (Model –
FFLE3911QW) & LC2 (Model – FFLG4033QW) and press
the Selector knob momentarily (<1 second). The other
knobs and switches do not matter.
2.
Within 5 seconds, move the temperature knob to
the far right position CW and push the Selector knob
momentarily (<1 second). Move the temperature selector to
the far left CCWand push the Selector knob momentarily
(<1 second). There will be a long beep signalling the entry
into the Diagnostic/Line Test Mode. If not, start over with an
effort to perform the series of events faster or with more
precision.
149
(Washer)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fflg3911qwFfle4033qwFflg4033qw

Table of Contents