Pre-Installation Requirements; Electrical Requirements; Water Supply Requirements; Drain Requirements - Frigidaire GLEH1642DS0 Installation Instructions Manual

Tumble action laundry center gas & electric
Hide thumbs Also See for GLEH1642DS0:
Table of Contents

Advertisement

Available languages

Available languages

PRE-INSTALLATION REQUIREMENTS

Tools and Materials Required for Installation:
1. Phillips head screwdriver
2. Channel-Iock adjustable pliers
3. Carpenter's level
4. Flat or straight blade screwdriver
5. Duct tape
6. Rigid or flexible metal 4 inch (10.16 cm) duct
7. Vent hood
8. Pipe thread sealer (Gas)
9. 1/4 inch socket w/ratchet
10. 3/8 inch socket w/ratchet
11. 3/8 inch open end wrench
12. 7/16 inch open end wrench
13. 9/16 inch open end wrench

ELECTRICAL REQUIREMENTS

ELECTRIC Laundry Center
Circuit- Individual 30 amp branch circuit fused with 30 amp
minimum time delay fuses or circuit breakers.
POWER SUPPLY - 3-wire or 4-wire, 240 volt, single phase,
60 Hz, Alternating Current.
POWER SUPPLY CORD KIT- The laundry center MUST
employ a 3-condutor power supply cord NEMA 10-30 type
SRDT rated at 240 volt AC minimum, 30 amp, with 3 open
end spade lug connectors with upturned ends or closed loop
connector OR a 4-condutor power supply cord NEMA 14-30
type SRDT or ST (as required) rated at 240 volt AC
minimum, 30 amp, with 4 open end spade lug connectors
with upturned ends or closed loop connectors and marked
for use with clothes dryers. If being installed in a
manufactured (mobile) home, the laundry center MUST
employ a 4-condutor power supply cord NEMA 14- 30 type
SRDT or ST (as required) rated at 240 volt AC minimum, 30
amp, with 4 open end spade lug connectors with upturned
ends or closed loop connectors and marked for use with
clothes dryers. See ELECTRICAL CONNECTIONS. (Canada -
4-wire power supply cord is installed on laundry center.)
OUTLET RECEPTACLE - NEMA 10-30R (3-wire) receptacle or
NEMA 14- 30R (4-wire) receptacle to be located so the
power supply cord is accessible when the laundry center is in
an installed position.
NEMA 10-30R
GAS Laundry Center
CIRCUIT -Individual 15 amp branch circuit fused with a 15
amp maximum time delay fuse or circuit breaker.
POWER SUPPLY -3 wire, 120 volt single phase, 60 Hz,
Alternating Current.
NEMA 14-30R
POWER SUPPLY CORD -The gas laundry center is equipped
with a 120 volt 3-wire power cord.
OUTLET RECEPTACLE - Properly grounded 3-prong receptacle
to be located so the power supply cord is accessible when the
washer is in an installed position. NOTE: GFI (Ground Fault
Interrupter) receptacle is not required or recommended.
NOTE: Do not under
any circumstances
remove grounding
prong from plug.

WATER SUPPLY REQUIREMENTS

Hot and cold water faucets MUST be installed within 42
inches (106.68 cm) of your laundry center's water inlet. The
faucets MUST be 3/4 inch (1.9 cm) garden hose type so inlet
hoses can be connected. Water pressure MUST be between
10 and 120 pounds per square inch (maximum unbalance
pressure, hot vs. cold, 10 psi). Your water department can
advise you of your water pressure. The hot water
temperature should be about 140 degrees F.

DRAIN REQUIREMENTS

1. Drain capable of eliminating 17 gallons per minute.
2. A standpipe diameter of 1¼ inches (3.18 cm) minimum.
3. The standpipe height above the floor should be:
Minimum height: 24 inches (61 cm)
Maximum height: 96 inches (244 cm)
24 in.(61cm)
NOTE:
For installations requiring a longer drain hose, have a
qualified technician install a longer hose, Part Number
134042901, available from an authorized parts
distributor. For drain systems in the floor, install a
siphon break kit, available from your local hardware
store .
2
Grounding Prong
96 in.
(244 cm)
Max.
Max.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lgh1642ds0

Table of Contents