E32: Electronic Pressure Sensor Calibration Problems - Frigidaire FFLE3911QW Technical & Service Manual

Table of Contents

Advertisement

E32: Electronic Pressure Sensor calibration problems

E32
Water inlet valve defective, Pressure Sensor defective, Drain pump defective,
Drain pipe blocked, wiring or Main Control Board
Checks to perform:
Is the air tube connected properly (check also for kinking
and leaking)? (Disconnect the tubes and blow into them to
make sure the system is unobstructed) (See Fig. 1)
Is the frequency of Pressure Sensor between 45 Hz to 45.5
Hz? (Measure it on the pressure sensor wiring connector at
Main Control Board when machine is owered with empty
tub (No water)) (See Fig. 2)
Is the resistance measurement of the
Solenoid Valve approximately 1375Ω
± 10% (Measure it directly on the
connector on the Main Control Board
side between terminals J20-1 & J20-3,
J18-1& J18-3 and J18-4 & J18-6
(See Fig. 3).
Is the drain pipe positioned correctly and not causing
the siphon effect? (See Fig. 5)
Is the resistance measurement of
the Drain pump approximately 12Ω
to 17Ω? (Measure it directly on
the connector on the Main Control
Board side between terminals J15-
3 & J15-4). (See Fig. 6)
Replace the Main Control Board and repeat the Diagnostic
Cycle to check for any further alarms.
Y
E
S
Y
E
S
measurement of the
Solenoid Valve approximately
1375Ω ± 10%? (Measure it
NO
directly on the solenoid valve
without wiring) (See Fig. 4)
Y
E
S
Y
E
S
Is the resistance
measurement of the
Drain pump approximately
NO
12Ω to 17Ω? (Measure it
directly on the Drain pump)
(See Fig. 7)
Y
E
S
defective.
WARNING
Check that all the connectors are correctly inserted.
Replace or Repair the air tube and repeat the Diagnostic
NO
Cycle to check for any further alarms.
Replace Pressure Sensor and repeat the Diagnostic
NO
Cycle to check for any further alarms.
Is the resistance
NO
Y
E
S
Check / Replace the wiring and repeat the Diagnostic Cycle
to check for any further alarms.
Repair the drain circuit and repeat the Diagnostic Cycle to
NO
check for any further alarms.
NO
Y
E
S
Check / Replace the wiring and repeat the Diagnostic
Cycle to check for any further alarms.
166
Replace the Solenoid Valve and repeat
the Diagnostic Cycle to check for any
further alarms.
Replace the Drain pump and repeat the
Diagnostic Cycle to check for any further
alarms.
E32