E58: Motor Over Current - Frigidaire FFLE3911QW Technical & Service Manual

Table of Contents

Advertisement

E58: Motor over current

E58
Foam or drum weight overload, Motor, wiring, Motor Control Board defective
Checks to perform:
Is the power supply as per product specification? (Voltage =
240V (Electric), 120V (Gas) Models.
Is the laundry load as per product specification? (Load
Capacity = 10.1 Kg (Approx.))
Remove the laundry and check whether the drum turns
freely without posing any resistance. Is the drum having any
difficulty in rotating? (See Fig .1)
Is the resistance measurement of the Motor approximately
6Ω to 8Ω ? (Measure it directly on the Motor terminals 1 &
2, 2 & 3, and 1 & 3 without wiring) (See Fig. 2)
Is the resistance measurement of Motor approximately 6Ω
to 8Ω? (Measure it directly on the Motor wiring connector
on the Motor Control Board side between terminals J2-1
& J2-2, J2-2 & J2-3 and J2-3 & J2-1) (See Fig. 3)
Replace the Motor Control Board and check for further
alarms. Is the appliance ok?
Y
E
S
Y
E
S
N
O
Y
E
S
Y
E
S
WARNING
Check that all the connectors are correctly inserted.
Make the power supply proper as per product
NO
specification and repeat the Diagnostic Cycle to check
Make laundry load as per product specification and
NO
repeat the Diagnostic Cycle to check for any further
Replace / Repair the defective component and repeat
YES
the Diagnostic Cycle to check for any further alarms.
Replace the Motor and repeat the Diagnostic Cycle to
NO
check for any further alarms.
Replace / Repair the wiring and repeat the Diagnostic
NO
Cycle to check for any further alarms.
Replace the Main Control Board and repeat the
NO
Diagnostic Cycle to check for any further alarms.
177
for any further alarms.
alarms.
E58