6.7 Water Supply Requirements

Install hot and cold water faucets within 42 inches (107 cm)
of your washer's water inlet. The faucets MUST be 3/4
inch (1.9 cm) with a threading for laundry hose connection.
Water pressure MUST be between 10 psi (0.69 bars) and
120 psi (8.27 bars). The pressure difference between hot
and cold water cannot be more than 10 psi. The water
department can advise you of the water pressure.

6.8 Drain System Requirements

1.
Drain capable of eliminating 17 gals (64.3 L) per minute.
2.
A standpipe diameter of 1-1/4 inches (3.18 cm)
minimum.
3.
The height of the standpipe above the floor should
51