Eb3:(Eh3): Power Supply Voltage Too Low; Ebe:(Ehe): Motor Control Board Relay Error; Ebf:(Ehf): Motor Control Board Relay Sensing Error - Frigidaire FFLE3911QW Technical & Service Manual

Table of Contents

Advertisement

EB3 (EH3): Power supply voltage too low
EB3 (EH3)
Low AC voltage input, Main Control Board defective.
Checks to perform:
IMPORTANT
The appliance remains in alarm status until the mains frequency returns
to the correct values or the appliance is switched OFF. Only the family of
the alarm is displayed and the Diagnostics Mode cannot be accessed. The
complete alarm can only be read when the situation has normalized.
Is the power supply as per product specification? (Voltage =
240V (Electric), 120V (Gas) Models
Replace the Main Control Board and repeat the Diagnostic Cycle to check for any further alarms.
EBE (EHE): Motor Control Board Relay error
EBE (EHE)
Motor Control Board relay defective, Main Control Board defective.
Checks to perform:
Check the wiring of motor. If it is proper replace the Motor Control Board and check problem is solved? If not sloved,
replace the Main Control Board and repeat the Diagnostic Cycle to check for any further alarms.
EBF (EHF): Motor Control Board relay sensing error
EBF (EHF)
Main Control Board defective
Checks to perform:
Replace the Main Control Board and repeat the Diagnostic Cycle to check for any further alarms.
Y
E
S
WARNING
Check that all the connectors are correctly inserted.
Make the power supply proper as per product
specification and repeat the Diagnostic Cycle to check
NO
for any further alarms.
WARNING
Check that all the connectors are correctly inserted.
WARNING
Check that all the connectors are correctly inserted.
191
EB3 (EH3)
EBE (EHE)
EBF (EHF)

Hide quick links: