9.7 Inlet Thermal Limiter
- FFLE3911QW and
FFLG4033QW
WARNING
When replacing the Inlet / Outlet Thermal Limiter,
refer to the code shown on the list of spare parts
related to the appliance.
Specifications
S.NO
Component
1
Inlet Thermal Limiter
9.8 Outlet Thermal Limiter
- FFLE3911QW
Specifications
S.NO
Component
1
Outlet Thermal Limiter
NOTE
Outlet Thermal Limiter is not applicable for FFLG4033QW Gas model.

9.7.1 General Characteristics

Limiter is a heat-sensitive fuse attached to the heating
element, and it disconnects
electrical power to the heater
when the dryer gets overheated.
The specific purpose of the
Thermal Limiter is to prevent
overheating and fire. It is made
of a heat-sensitive material that
melts or otherwise becomes
electrically open when the temperature rises beyond its limit.
Specifications
U.L. and C.S.A . Rated:125/250 VAC 25 A Resistive,
125 VAC, 20 F.L.A.,60 L.R.A. Inductive,
240 VAC, 10 F.L.A., 60 L.R.A. Inductive,
Opening Temp: 275º ± 10.8ºF, Closing Temp: -31ºF.
9.8.1 General Characteristics
It is a heat-sensitive fuse attached to the rear panel, and it
disconnects electrical power to the heater when the dryer
gets overheated.
The specific purpose of the Thermal Limiter is to prevent
overheating and fire. It is made of a heat-sensitive material
that melts or otherwise becomes electrically open when the
temperature rises beyond its limit.
Specifications
U.L. Rated : 240V, 10A F.L.A and 60A L.R.A at 350ºF,C.S.A .
Rated: 120V 15A Resistive, Opening Temp: 222º ± 8ºF,
Closing Temp: -31ºF.