E5H: Motor control under voltage

E5H
Low input AC voltage, Wiring or motor control board, Main board.
Checks to perform:
Is the power supply as per product specification? (Voltage =
240V (Electric), 120V (Gas) Models and Frequency = 60HZ)
Is the wiring between Main Control Board and Motor
Control Board proper? (Check for the continutity)
Replace the Motor Control Board and check for further
alarms. Is the appliance ok?
E5H: Motor control under voltage
E5C
Low input AC voltage, Wiring or motor control board, Main board.
Checks to perform:
Replace the Motor Control Board and check for further
alarms. Is the appliance ok?
Is the wiring between Main Control Board and Motor
Control Board proper? (Check for the continutity)
Replace the Motor Control Board and check for further
alarms. Is the appliance ok?
Y
E
S
Y
E
S
Y
E
S
Y
E
S
WARNING
Check that all the connectors are correctly inserted.
Make the power supply proper as per product
NO
specification and repeat the Diagnostic Cycle to check
for any further alarms.
Replace / Repair the wiring and repeat the Diagnostic
NO
Cycle to check for any further alarms.
Replace the Main Control Board and repeat the
NO
Diagnostic Cycle to check for any further alarms.
WARNING
Check that all the connectors are correctly inserted.
Replace the Main Control Board and repeat the
NO
Diagnostic Cycle to check for any further alarms.
Replace / Repair the wiring and repeat the Diagnostic
NO
Cycle to check for any further alarms.
Replace the Main Control Board and repeat the
NO
Diagnostic Cycle to check for any further alarms.