8.- TEMPERATURE SELECTION

8.1.- Selecting the boiler set point temperature

The desired boiler operating temperature is selected using the touch button, as shown in the
figure. To select the desired temperature, touch the "+" or "-" symbols to increase or decrease
the temperature respectively. When the temperature has been selected, the display will
return to standby mode after a few seconds.
The boiler setpoint temperature can also be selected by using the MODE touch button to
browse to the "boiler setpoint temperature" display option. When the display shows this
option, touch the "+ /-" symbols to select the desired temperature.
If you wish to totally disable the boiler heating function (Summer mode), select the setpoint
value "OFF" by touching the "-" symbol until this value appears on the display.
The permitted boiler setpoint temperature range is OFF and 30 - 85 ºC. TRO Evolution System
model boilers are condensing boilers. In order to obtain maximum boiler performance and
energy savings, it is therefore recommended to select a setpoint temperature of 55-70 ºC,
providing this is permitted by the heating system installed and the insulation conditions of
your home.

8.2.- Selecting the DHW setpoint temperature (with hot water tank only)

The desired DHW temperature is selected using the touch button, as shown in the figure. To
select the desired temperature, touch the "+" or "-" symbols to increase or decrease the
temperature respectively. When the temperature has been selected, the display will return to
standby mode after a few seconds. The DHW setpoint temperature range permitted is OFF
and 15 - 65 ºC.
The DHW setpoint temperature can also be selected by using the MODE touch button to
browse to the "DHW setpoint temperature" display option. When this option appears on the
display, touch the "+ /-" symbols to select the desired temperature.
If you wish to totally disable the boiler's DHW production function, select the setpoint value
"OFF" by touching the "-" symbol until this value appears on the display.