Page 1
Greenflame Eco 10-60kW Installation Manual Greenflame Eco Wood Pellet Boiler 10-60kW Installation, Operation and Servicing Instructions PLEASE NOTE: This product MUST be commissioned by a T R Engineering Ltd approved engineer. INSTALLER Have you been trained by T R Engineering Ltd to commission this appliance? If you intend to commission and do not have a T R Engineering Ltd Cert No.
Greenflame Eco 10-60kW Installation Manual Contents 1. Introduction 2. Warnings and Guarantee/Warranty Information 2.1 Safety Instructions 2.2 Operating Warnings 2.3 Guarantee/Warranty Information 2.3.1 Limitations 2.3.2 Exclusions 2.4 Clean Air Act 1993 2.5 Customer Handover 3. After Sales Service Information 3.1 How to Report a Fault 3.2 Technical Assistance...
Greenflame Eco 10-60kW Installation Manual 1. Introduction 2. Warnings Guarantee/Warranty Conditions Dear Customer, We wish to thank you for choosing this Greenflame wood pellet boiler 2.1 Safety Instructions product from T R Engineering Ltd. In order to get the best performance from your appliance we recommend that you read this booklet carefully before lighting the appliance for the first time.
Greenflame Eco 10-60kW Installation Manual Do not wash the inside of the heat exchanger with water. 2.3.1 Limitations Do not wash the appliance with water. The water could get inside the The above guarantee does not cover parts subject to normal wear such unit and damage the electrical insulation and cause electric shocks.
1993 including designation and supervision. accepted unless authorised in advance by T R Engineering Ltd. The Greenflame ECO wood pellet boiler 10, 15, 25, 40 and 60kW have 3.2 Technical Assistance been recommended for exemption under section 21 of the Clean Air Act 1993 for use within UK Smoke Control Areas.
The user is fully responsible for the usage and maintenance of the The Greenflame Eco has been recommended as suitable for use in boiler. smoke control areas when burning ENplus-A1 wood pellets.
The lids and front doors may need to be removed for access through a standard doorway. The above parameter comparison for Greenflame Eco pellet boilers is tentative. The manufacturer reserves the right to small variations to some values in the above table.
Exhaust fumes created in the process are directed through the heat A standard Greenflame Eco pellet boiler consists of: exchanger to the chimney outlet through the chimney duct which ...
Greenflame Eco 10-60kW Installation Manual buildings. In most cases, to determine flue parameters should be 6. Setting Up and Installation of the Boiler calculated according to Current Building Regulations. 6.1 Engineer’s Responsibilities Improper cross-sectional area selection causes slowdown of exhaust fumes and in turn, deposition of ash inside the flue.
Greenflame Eco 10-60kW Installation Manual 6.4.1 Electrical Schematic White/green White brown black blue black black black black black black...
Page 16
Greenflame Eco 10-60kW Installation Manual blue black black black black white blue white black black black black black blue black black black black black...
Greenflame Eco 10-60kW Installation Manual Remove gas strut from hopper lid. 6.4.3 Auger Set-Up (Optional) Mains In Locate vacuum unit to hopper. Locate vacuum lid unit on to existing hinges on the hopper. To pellet sensor To auger Locate pellet loader controller to lid using existing cut-out.
Page 19
Greenflame Eco 10-60kW Installation Manual Controller Functions Main Page The main page is shown in the LCD display during normal operation with the following data displayed on it. Current time Low Current Time Feeder current (mA) This should be set at 4s so when the mA value drops below the ...
Greenflame Eco 10-60kW Installation Manual DO NOT install the unit with the power on (make sure that the plug is Submenus are used to display and change operation parameters. In disconnected from the main supply). order to change a parameter, press “ENTER”...
Greenflame Eco 10-60kW Installation Manual 6.5.2 Amount of Air, Lambda Sensor – Power Test Mode Correction due to Lambda sensor (+/- 10) The combustion process requires the supply of oxygen, the amount of which depends on the type of fuel and the power of the heating unit.
Greenflame Eco 10-60kW Installation Manual No Light/No Fuel – the alarm is activated if the suction system has made three consecutive failed attempts to ignite the fuel. BOILER NOTE!! Once an alarm has been activated you should determine and >>...
Greenflame Eco 10-60kW Installation Manual Remember that the start-up of the boiler should be performed Service only by personnel trained by T R Engineering Ltd with a current Isolate the appliance from the mains supply and test safe. authorised service certificate.
Greenflame Eco 10-60kW Installation Manual 9. Service Schedule Date of Repair Description of Conducted Work Stamp and Signature of Service Person...
Page 30
Greenflame Eco 10-60kW Installation Manual T R Engineering Ltd Unit 7, Newton Chambers Way Chapeltown, Sheffield, S35 2PH Telephone: +44 (0)114 257 2300 Fax: +44 (0)114 257 1419 Email: info@trianco.co.uk Web: www.trianco.co.uk T R Engineering Ltd is a company registered in England and Wales Registration no. 7321802 Copyright of all contents of this leaflet is vested in T R Engineering Limited.