Connect the Hall sensors from your motor according to Figure 4-5 (page 2-2). Note that color codes are shown for
®
Kollmorgen SILVERLINE
from other manufacturers can be used. If you are connecting a brush motor, leave J7 open and remove J2; there is no
need to jumper any sensor lines.

4.9.10 Wiring JB1, Bus Power Out

JB1 is a 2-pin pluggable screw terminal. Pin 1 is ground; Pin 2 is bus.
JB1 is designed to provide control power for option cards. Do not use JB1 for bus power.
JB1 provides limited power
for option cards. Do not use
JB1 for bus power.
CAUTION

4.9.11 Wiring JL1, Logic Out

JL1 is a 4-pin crimp connector. JL1 provides logic power for the velocity loop option card. It is only for factory
connections.
JL1 is for factory connections
only.
CAUTION
®
SILVERLINE
Product Family
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table 4-4 Connector J7: Hall Sensor
Pin
Signal Name
1
Hall Sensor Power
2
Hall Sensor Common
3
Sensor S1
4
Sensor S2
5
Sensor S3
and RBE motors. (For Kollmorgen VMG motors, see Figure 4-6 on page 4-21.) Motors
Table 4-5 Connector JB1: Bus Out (low Power)
Pin
Signal Name
1
BUS (-) (Common)
2
BUS (+)
Table 4-6 Connector JL1: Logic Out
Pin
Signal Name
1
Common
2
+5
3
+15
4
-15
Mounting and Wiring
Color
Blue
Green
Brown
Orange
Yellow
4-12