Kollmorgen
Rectifier Bridge
AC
AC
F1
1
2
3
4
Line Voltage
(120 VAC shown)
SPS(R) Terminal Strip Wiring
1 & 4:
AC Line (120 VAC or 240 VAC)
2 & 3:
115/230VAC Select:
For 110VAC: Connect 1-2 and 3-4
For 230VAC: Connect 2-3
5 & 6:
Bus + (4 Connections)
7 & 8:
Bus - (4 Connections)
Two FACTORY
"insertion points."
Two CUSTOMER
"insertion points."
Figure 4-1 SPS/R-4008-4 Field Wiring with Detail of Terminal Strip
®
SILVERLINE
Product Family
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Optional
Regen
Unit
+
-
J3-1(+)
J3-4 (-)
F2
5
6
7
8
Mounting and Wiring
BJx
BJx
#1
#2
J1-2
J1-1
J1-5
J1-4
J1-5
(-)
J1-4
(+)
(-)
(+)
(-)
Customer Provided Connections
Note: F1 and F2 are 250V,
1.5 A, 3AG Fuses.
1
2
3 4 5 6 7 8
Each terminal has 4 "Insertion
Points" which are all electrically
connected. The bottom two are
provided for CUSTOMER
connections. The top two are
reserved for factory connections.
Do not insert more than one wire in
each point.
SPS(R)-4008-4
BJx
BJx
#3
#4
J1-2
J1-2
(+)
J1-5
J1-4
(-)
J1-5
J1-4
(-)
(+)
(-)
(+)
(-)
4-15

Advertisement