Kollmorgen SILVERLINE S/O Series Manual page 17

Table of Contents

Advertisement

Kollmorgen
ESD Protection
Current Overload
Analog Input
AMP OK
ENABLE
Main DC Bus: Minimum
Output Current (40°C Ambient)
Output VA (@ 40 V BUS & 40°C Ambient)
PWM Switching Frequency
Overvoltage Trip
Encoder Supply Max
Linearity
Velocity Range
Differential Input
Max Frequency
®
SILVERLINE
Product Family
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
ANALOG CMD inputs resistor/diode protected.
ENABLE input opto-isolated.
AMP OK output opto-isolated and buffered.
Hall sensor inputs resistor / diode protected.
Monitor Current
Full Differential, ±10 volts
Impedance: Approximately 40 kohm
Max Current sink:24 mA (Customer must supply impedence)
Voltage Range: 5-26V, impedance limited by customer
Voltage Range: 5-26V
Maximum Load for 12 mA @ 26V (2.5 mA @ 5V)
Table 2-1 Specifications
SO-40XX
DESCRIPTION
Maximum
Continuous
Peak (2.0 sec)
Continuous
Peak (2.0 sec) (RMS)
Table 2-2 Specifications
Velocity Loop Option
System Description
SO-4004 SO-4008
20 VDC
20 VDC
40 VDC
40 VDC
4 ADC
8 ADC
8 ADC
16 ADC
160 VA
320 VA
320 VA
640 VA
18 kHz
18 kHz
43 VDC
43 VDC
250 mA
0.2% Full Scale
2000:1
±10 VDC
384 kHz
2-4