Synchronous Control Parameter Settings - Mitsubishi Electric MELSEC iQ-R Series Quick Start Manual

Servo system, simple motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

4.3.4 Synchronous control parameter settings

Set parameters for Axis 1 which synchronizes to the input axis (Axis 2) feed current value in cam operation.
Item
Input axis parameter
Axis 1 synchronous control parameter
Synchronous control image
1.
Synchronous parameter settings
The following explains the settings that synchronize Axis 1 to the feed current value of Axis 2.
1. If you select [Main shaft (Main)], the [Type] for the Main input axis will be selected.
2. Set [Pr.400 Type] to "1: Servo Input Axis", and [Pr.400: Axis No.] to "2".
1.
4 SYNCHRONOUS CONTROL STARTUP
54
4.3 Parameter Creation for Synchronous Control
Description
Set the servo input axis type for the main shaft.
(Set "1: Feed current value " for Axis 2)
Set the Axis 1 synchronous control parameter.
The configuration of output axes connected to the main shaft is displayed.
The configuration of input/output axes can be checked at a glance.
2.

Advertisement