4.4.3 Operation check with digital oscilloscope

The section explains how to check the cam operation with the assistant function of digital oscilloscope.
1.
Start of digital oscilloscope
1. Select [Digital Oscilloscope] from the menu.
2.
Selecting probe
1. Click [Assistant Screen] to open the Assistant window.
2. Click [Select the probe item to be sampled.] to open the Assistant (Probe Selection).
3. Select [Cam operation] from "List by specified purpose".
4. Select the axis No.
3.
Sampling condition settings (No need to change)
Change the sampling condition where necessary.
In this example, the default values are used.
4 SYNCHRONOUS CONTROL STARTUP
64
4.4 Operation Check for Synchronous Control
1.
1.
2.
3.
View video: