Connect Hardware for TDMS/EADAS Data Link

PROCEDURE
1.
Verify that the internal jumpers of the RS422 to RS232 converter (ED5D764-30
G17A, Black Box # IC456A-R4) are set as illustrated in Figure 8.11.3-1
To 120VAC
on UPS
XW1A XW2A XW3A XW4A XW4B XW5A XW5B
XW1B XW2B XW3B
Figure 8.11.3-1 — DIP Shunt Settings for IC456A-R2
.
2.
Connect the RS422 cable (ED5D764-30 G106, Black Box # EDN37J-00XX-MM;
where XX is the cable length in feet) between port 3 on the High Speed Interface
(HSI) and the RS422 port on the converter.
3.
Connect the RS232 male to male cable (Black Box # ECM25C-0010-MM) from the
RS232 port on the converter to the Data Communication Equipment (DCE),
which may be a modem, DSU2, or router.
4.
Plug the converter's AC power adapter into a UPS 120VAC outlet. Refer to
Figures 8.11.3-2 , 8.11.3-3 and 8.11.3-4 for an illustration of the wiring
configuration for the TDMS/EADAS or RMAS data link.
1. Trademark of Sun Microsystems, Inc.
Issue 3.00B
RS422
RS232
port
port
RS422 to RS232 Con verter
(viewed from top with co ver off)
GROWTH AND DEGROWTH
Procedure 8.11.3
= DIP equipped with shunt
Page 8.11.3-1