235-200-150
January 2003
5.10.2

Populate Low Level ECD Forms for TTY Port

PROCEDURE
Note:
The following low level ECD activity allows the balance output to be directed
to an existing TTY port.
1.
At the MCC terminal, type and enter: 199 to access the Equipment Configuration
Database (ECD).
Response:
1. database_name:
2.
Type and enter: incore
Response:
2. review only
3.
Type and enter: n
Response:
3. journaling
4.
Type and enter: *
Response:
Enter Form Name:
5.
Type and enter: trbegin
Response:
tr_name
6.
Type and enter: <ret>
Response:
Enter Execute, Change. . .
7.
Type and enter: e
Response:
Enter Form Name:
8.
Type and enter: classdef
Response:
Enter Database Operation
I=Insert, R=Review, U=Update, D=Delete
9.
Type and enter: u
Response:
class_name
10. Type and enter:
196
Response:
Enter Update, Change . . .
11.
Type and enter: c
Response:
Change field
12. Type and enter: 3
Response:
row
13. Type and enter:
1 (if row 1 value is null or value is being replaced)
or
20 (if additional devices are being added to the current list)
Response:
1) or 20)
14. Type and enter: (logical device port assignment, for example, rop0)
Issue 3.00