Restore Power To Administrative Workstation Units ( Netra 240) - Lucent 5ESS DRM User Manual

Distinctive remote module
Table of Contents

Advertisement

235-200-150
October 2005
Restore Power to Administrative Workstation Units ( Netra
4.10
OVERVIEW
This procedure will restore power to the Netra 240 AW and the external DAT tape
drive.
PROCEDURE
1.
Restore power to the DAT tape drive unit. See "Restore Power to DAT Tape Drive
Unit (Netra 240)", Procedure 4.16.
2.
Connect the DC power cables A and B to the AW. See Figure 2-7.
3.
Close the circuit breakers for the DC power cables A and B. To close the circuit
breaker, insert the fuse by pushing in the fuse while turning it clockwise. The
fuse-alarm LED above the fuse will no longer be lit when the fuse is properly
seated.
4.
Restore power to the replacement AW by pressing the ON/STBY switch "
the front of the AW and holding it until the system starts to power up. The green
system power LED, located on the upper left corner of the front cover, will be lit.
5.
The AW will automatically boot on the 3B21 Emulator and Operating System
software.
6.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.