Update RC/V 8.1 for TDMS/EADAS Data Link

PROCEDURE
1.
At the MCC or STLWS, type and enter 196 to enter Recent Change and Verify.
Response:
PRINT OPTION CR = N ___
DETAIL OPTION CR = N
VERBOSE OPTION CR = N
INPUT Y or N
2.
Enter CARRIAGE RETURN 3 times to get to the RECENT CHANGE AND
VERIFY CLASSES page.
3.
Type and enter: 8.1u to update recent change view 8.1.
Response:
OFFICE PARAMETERS (MISCELLANEOUS) page displayed.
Cursor at OFFICE ID attribute.
4.
Type and enter the appropriate OFFICE ID for field 1.
Response:
System completes remainder of form.
Enter Insert, Change, Validate, or Print:
5.
Type and enter: c
Response:
Change Field:
6.
For 5E14, type and enter EADAS
Response:
Cursor at EADAS LINK attribute.
For 5E15 and later, type and enter TRFM
Response:
Cursor at TRFM LINK attribute.
7.
Type and enter: y
Response:
Change Field:
8.
Enter CARRIAGE RETURN
Response:
Enter Update, Change, Validate, or Print:
9.
Type and enter: u
Response:
updating.....FORM UPDATED
OFFICE PARAMETERS (MISCELLANEOUS) page displayed.
Cursor at OFFICE ID attribute.
10. Type and enter: <
Response:
8.0 OFFICE MISCELLANEOUS AND ALARMS VIEWS page
displayed.
11.
Type and enter: q to quit Recent Change.
Response:
RCV-196 COMPLETED
12. THIS IS A SAFE STOPPING POINT.