Perform Tdms/Eadas Data Link Growth - Lucent 5ESS DRM User Manual

Distinctive remote module
Table of Contents

Advertisement

235-200-150
January 2003
8.11

Perform TDMS/EADAS Data Link Growth

OVERVIEW
This procedure is used to grow in the Traffic Data Management System/Engineering
and Administrative Data Acquisition System (TDMS/EADAS) BX.25 data link using
ECD low-level forms. The TDMS/EADAS data link supports Lucent's TDMS
operations system that is used to collect traffic data from the switch.
This procedure assumes the TDMS/EADAS link is to be grown on port 3 of the DRM's
high speed interface (HSI). This procedure also assumes that the SCANS link is on
HSI port 0 and the AMA link is on HSI port 1. This procedure makes adjustments
based on whether the optional SCC data link is grown in on HSI port 2.
The following hardware must be on site:
RS422 to RS232 converter (Black Box part # IC456A)
RS422 cable (Black Box part # EDN37J-00XX-MM; where XX is the cable length
in feet)
RS232 cable (Black Box part # ECM25C-0010-MM)
This procedure takes approximately 2 to 3 hours to complete.
PROCEDURE
1.
This process is a combination of procedures. Perform these procedures in the
order in which they are presented.
1.
"Grow in TDMS/EADAS Data Link in ECD," Procedure 8.11.1.
2.
"Update RC/V 8.1 for TDMS/EADAS Data Link," Procedure 8.11.2.
3.
"Connect Hardware for TDMS/EADAS Data Link," Procedure 8.11.3.
4.
"Define TDMS/EADAS Port on TDMS System," Procedure 8.11.4.
5.
"Initialize TDMS/EADAS Processes," Procedure 8.11.5.
6.
"Restore TDMS/EADAS Data Link to Service," Procedure 8.11.6.
7.
"Verify Operation of TDMS/EADAS Data Link," Procedure 8.11.7.
8.
"Backup Office Dependent Data", Procedure 8.11.8
Issue 3.00
GROWTH AND DEGROWTH
Procedure 8.11
Page 8.11-1