Figure 22: Timing Signals - Datalogic VLASE IR 1PWX-TLS2 User Manual

Marking systems
Table of Contents

Advertisement

TECHNICAL SPECIFICATIONS
2.4.3.4 MARKING PROCESS SIGNAL TIMING
The following diagram illustrates the possible timings and settings of these signals:
The time intervals in the diagram can all be programmed with a resolution of 1 ms
T
Start Time
1
T
Start Delay
2
T
Busy Advance
3
T
Stop Time
4
T
Busy Delay
5
T
End Time
6
(*) Refer to Lighter user's manual "Setting I/O parameters" to set the signal properties.

Figure 22: Timing signals

For setting the minimum acceptable time for the START_MARKING signal
For delaying the start of marking process
BUSY signal corresponding to marking progress
The minimum time for STOP_MARKING signal to stop the marking process
For delaying the Laser END signal with respect to laser emission
For setting the Laser END activation time
.
(*)