Signal Group (Sst+Sign?) - Christie Crimson Series Technical Reference

Status system
Hide thumbs Also See for Crimson Series:
Table of Contents

Advertisement

#
Status

Signal Group (SST+SIGN?)

The Signal Group provides values and fault conditions relating to the video signal status for Crimson.
#
Status
0
HDBaseT Input
11
Card 1 - Input 1
12
Card 1 - Input 2
13
Card 1 - Input 3
14
Card 1 - Input 4
21
Card 2 - Input 1
22
Card 2 - Input 2
23
Card 2 - Input 3
24
Card 2 - Input 4
50
Output Frequency
Crimson and Crimson Mirage Technical Reference–Status System
020-102661-04 Rev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
State
Value
Detection Fault
Upgrade Failure
State
Value
Not Present
<input type> (No Signal)
<input type>, <active
window>@ <v-sync rate>
(<status>)
<input type> <active window>
@ <v-sync rate> (<status>)
<rate>Hz
Crimson status system
Description
The upgrade should not take longer than
one minute and occurs immediately
following a main system software
upgrade.
Cannot detect the combiner.
Cannot upgrade the combiner firmware.
The projector will not turn on.
Description
Either the card is not present or the card
does not have a single input port.
No signal is detected.
Where <input type> : {DP, HDMI, DVI,
3G-SDI}
Where
<input type> : {DP, HDMI, DVI, 3G-
SDI}
<active window> :
<columns>x<rows>
<v-sync rate> : the input frame rate,
in Hz (##.##Hz)
<status> : {"Master", "No signal",
"Inactive", "Locked"}
Where
<input type> : {DP, HDMI, DVI, 3G-
SDI}
<active window> :
<columns>x<rows>
<v-sync rate> : the input frame rate,
in Hz (##.##Hz)
<status> : {"Unlocked", "Out of
phase"}
Where <rate> : the output frame rate,
in Hertz
If the input frequency does not match
the output frequency, Free Running @
XX.YYHz is displayed.
12