Christie Crimson Series Technical Reference page 8

Status system
Hide thumbs Also See for Crimson Series:
Table of Contents

Advertisement

#
Status
12
Keypad Display
13
Power Supply
Crimson and Crimson Mirage Technical Reference–Status System
020-102661-04 Rev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
State
Value
Communication Fault
Auto Detect
Programming
OK
Detection Fault
Unexpected Behavior
Upgrade Failed
OK
Unknown
Fan Problem
Overtemperature
Overtemperature/Fan
Problem
Communication Fault
Detection Fault
Overvoltage Detected
Overcurrent Detected
Overtemperature
Overtemperature/Fan
Problem
Crimson status system
Description
The device failed to respond or it
provided a bad response to a command
while the projector is in standby mode.
The projector is attempting to detect the
presence of the keypad display device.
Programming the device with the correct
firmware.
The device has been properly detected
and initialized.
Cannot detect the keypad display device.
The device is not responding correctly.
The device failed to upgrade properly.
The power supply has been properly
detected and initialized.
The status of the power supply is
unknown due to an upstream
communication fault.
The power supply reports a fan failure
but no over temperature shutdown or
high temperature alarm is reported.
The power supply reports a high
temperature alarm but reports no fan
failure.
The power supply reports both a high
temperature alarm and a fan failure.
Communication either timed out or an
error occurred in the transmission/
reception of data.
Communication timed out at startup.
The power supply reports an over
voltage shutdown condition.
The power supply reports an over
current shutdown condition.
The power supply reports an over
temperature shudown.
The power supply reports an over
temperature shutdown and fan failure.
8