Status
51
Frame Locked
52
3D Sync
53
TSIC Connection

Light Group (SST+LGHT?)

The Light Group provides values and fault conditions relating to the light source status for Crimson.
#
Status
0
Combiner State
Crimson and Crimson Mirage Technical Reference–Status System
020-102661-04 Rev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
State
Value
N/A
N/A
Locked
Unlocked
N/A
Valid 3D Sync
Internal 3D Sync
Valid HDMI 3D Sync
Invalid 3D Sync (using internal
sync)
No 3D Sync (using internal sync) Cannot detect an external 3D sync. The
Alias IP: <IP address>
N/A
State
Value
On
Off
Crimson status system
Description
No video is being displayed.
No video is being displayed or an
internal test pattern is being displayed.
The output is locked to the selected
input(s).
The output is not locked to the selected
input(s).
There is no 3D signal or 3D mode is set
to Off.
Detects a valid external 3D sync.
The system is using the internal v-sync
signal because the video is configured as
a Dual-Input. External sync is ignored.
Properly detects the built-in HDMI 3D
sync signal.
Detects an external 3D sync but it is not
locked and/or in phase with the 3D video
signal(s). The system is using the
internal v-sync signal instead but may
have L/R swapped.
system is using the internal v-sync
signal instead but may have L/R
swapped.
Displays the IP address used to
communicate with the projector through
the SDVoE network.
Either the card is not present or is not
powered.
Description
The combiner is on.
The combiner is off.
13