Christie Crimson Series Technical Reference page 7

Status system
Hide thumbs Also See for Crimson Series:
Table of Contents

Advertisement

#
Status
5
Lens Motor Horizontal-Axis
6
Lens Motor Vertical-Axis
7
Lens Motor Zoom- Axis
8
Lens Motor Focus- Axis
9
Built-In Self Test
10
System ID Board
11
Housekeeping Board
Crimson and Crimson Mirage Technical Reference–Status System
020-102661-04 Rev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
State
Value
Calibrating
Calibrated
Unknown
Uncalibrated
Failed
N/A
Passed
Failed
OK
Unknown
Communication Fault
Invalid Data
OK
Unknown
Communication Fault
Detection Fault
Initialization Fault
Crimson status system
Description
Currently calibrating the lens motor.
The motor range has been properly
calibrated.
The status of the motor is unknown
because a problem occurred in the
upstream communication path.
The range for the current lens has not
been determined and/or the reported
position on the axis may be inaccurate.
During reset or calibration, an error was
detected related to the motor and/or
sensor.
The built-in self test has not been
executed yet.
The built-in self test completed
successfully.
The built-in self-test failed.
The device has been properly detected
and initialized.
The status of the device is unknown.
Cannot communicate with the device.
The information on the device is missing
or corrupted.
The device has been properly detected
and initialized.
The status of the device is unknown.
The device failed to respond or provided
a bad response to a command while the
light source is on.
The projector remains on until AC power
is removed, even if this warning
condition is fixed.
Cannot read the device hardware
information.
Cannot properly initialize the device.