Chapter 3 Appendix
Error Message
C11D
BMC is in Forced Boot
Mode.
C200
The error occurred during
memory configuration
check.
C201
Memory Configuration
change is detected.
The error occurred during
C202
CPU configuration check.
C203
CPU Configuration change
is detected.
C300
Out-of-band setup
configuration failure
C301
SDR mismatch error
C310
Hardware
configuration of
cooling is
insufficient.
C320
Unmatched PSUs.
C321
System power
consumption is
out-of-range in PSUs.
C322
No information for
system power
consumption check.
ME is in Recovery Mode. Intel(R) Node Manager is in
C501
Cause
Detected that BMC is in Forced
Boot Mode.
Memory configuration could not
be obtained.
The memory configuration has
changed since the previous
startup.
The CPU information could not
be obtained.
The CPU configuration has
changed since the previous
startup.
Configuration change requested
by remote terminal via network
failed.
Inconsistency in the hardware
information of the sensor data
record was detected
Detected that cooling power is
insufficient in this hardware
configuration.
Unmatched power supply units
are configured.
System power consumption
exceeds the power output
capacity limit.
No information is acquired in
checking system power
consumption.
Recovery Mode.
Express5800/E120d-1 Maintenance Guide
Solution
Check the jumper switch setting on motherboard.
Unplug the power cord, wait for at least 30 seconds,
then restart the server. If the same error is detected
repeatedly, contact your sales representative.
Contact your sales representative.
When Check previous system Config is enabled in
Server of the setup, this message appears if the
configuration was changed since the previous startup.
If this message appears even when no configuration
change has been made, contact your service
representative.
Contact your sales representative.
When Check previous system Config is enabled in
Server of the setup, this message appears if the
configuration was changed since the previous startup.
If this message appears even when no configuration
change has been made, contact your service
representative.
Unplug the power cord, wait for at least 30 seconds,
then restart the server. If the same error is detected
repeatedly, contact your sales representative.
Contact your sales representative.
Check the installation status of power supply units.
Unplug the power cord, wait for at least 30 seconds,
then restart the server. If the same error is detected
repeatedly, contact your sales representative.
Check the jumper switch setting on motherboard.
Unplug the power cord, wait for at least 30 seconds,
then restart the server. If the same error is detected
repeatedly, contact your sales representative.